The OLP Optical Protection Board monitors optical power levels and provides low insertion loss for protected paths. It supports both 1+1 and 1:1 protection schemes, ensuring minimal signal loss during switching. The board features high measurement accuracy and fast switching times, making it suitable for critical network applications. It is compatible with various network management methods and meets major safety and EMC standards. Its robust design ensures reliable performance under a wide range of environmental conditions.
Product Overview:
- The OLP Optical Protection Board ensures continuous communication by providing reliable protection for optical signals. It is designed to switch to a backup path in case of a primary line failure, maintaining network integrity.
Description:
- The OLP Optical Protection Board monitors optical power levels and provides low insertion loss for protected paths. It supports both 1+1 and 1:1 protection schemes, ensuring minimal signal loss during switching. The board features high measurement accuracy and fast switching times, making it suitable for critical network applications. It is compatible with various network management methods and meets major safety and EMC standards. Its robust design ensures reliable performance under a wide range of environmental conditions.
Key Features:
- Reliable protection for optical signals
- Low insertion loss for protected paths
- Support for 1+1 and 1:1 protection schemes
- High measurement accuracy and fast switching times
- Compliance with major safety and EMC standards
Wavelength Range:
- Supports 1310±50nm and 1550±50nm, suitable for a wide range of optical communication applications.
Monitored Optical Power Range:
- Tx: +25dBm to -50dBm
- Rx: +10dBm to -50dBm
Insertion Loss:
- 1+1 Protection: ≤4.0dB
- Transmitter End: ≤1.5dB
- 1:1 Protection: ≤1.5dB
Switching Time:
- ≤20ms, ensuring rapid protection switching and minimal disruption to signal transmission.
Optical Power Measurement Accuracy:
- <0.5dB for +20dBm to -50dBm
- ≤1.0dB for -40dBm to -50dBm
Optical Power Resolution:
- ≤0.01 dB, providing precise optical power measurements.
Wavelength Dependent Loss:
- ≤0.25dB, ensuring minimal signal loss due to wavelength variations.
Polarization Dependent Loss:
- ≤0.1dB, ensuring high signal quality with minimal impact from polarization changes.
Return Loss:
- 45dB, providing excellent signal reflection performance.
Crosstalk:
- 55dB, ensuring high-quality signal isolation.
Network Management Methods:
- Supports CLI, NetRiver, and Web-based management, ensuring comprehensive control and monitoring.
Dimensions:
- Measures 177 (W) x 20 (H) x 225 (D) mm, making it a compact and efficient solution for optical protection.
Environmental Requirements:
- Operating Temperature: -10°C to 70°C
- Storage Temperature: -40°C to 80°C
- Humidity: 5% to 95% non-condensing
Power Consumption:
- Operates with a power consumption of less than 5W, ensuring energy efficiency while providing robust optical protection.